Model 33 Spellers are designed for applications where electric circuits are to be flashed in particular sequences such as with spelling or other animation. Variable in both cycle speed and cam cut, Model 33 Spellers are some of the most versatile sign controllers available. Spellers can be built with as few as one circuit, or as many as necessary to accommodate the required flashing sequence. Neon can be controlled by installing the speller on the primary side of transformers.




Model 33 Speller

All Model 33 Spellers are supplied with a standard 115 volt motor and are UL and cUL listed. Available with 220 volt motor by special order.


HOW TO ORDER A MODEL 33 SPELLER

All Model 33 Spellers are custom made. To order a Model 33 Speller, you will need to specify three key elements; namely the number of circuits, the speed, and the flashing sequence.

First, you will need to determine the number of circuits required. Each distinct section of the items to be animated will require its own circuit. The number of circuits is specified in the part number; for example a 33-S6M has 6 circuits.

Next you will need to determine the speed, or how quickly you want the speller to complete its performance. Speed ranges are easily adjustable in the field, so specifying an exact time is not necessary. Model 33 Spellers are available in 4 adjustable speed ranges as follows

Fast (F)..................................2 to 8 seconds per cycle
Meduim (M) ..........................4 to 20 seconds per cycle
Slow (S) ................................8 to 40 seconds per cycle
Extra Slow (XS) .....................18 to 90 seconds per cycle

Not all Spellers are available in all speed ranges. In general, the larger the speller the slower the speed ranges available. Specific speed range availability is based on the number of circuits as follows:

Number of Circuits Speed Ranges Available
5 and fewer F, M, S, XS
6 through 10 M, S, XS
11 through 15 S, XS
16 through 20 XS

Finally, you will need to specify a flashing sequence. To aid customers in communicating the flashing sequence, we have developed the sequence charting system shown below. You can use one of these standard sequences, or develop a custom sequence of your own. Virtually any sequence can be constructed.

The term "cycle" refers to the time required for the flashing action to complete its performance and start to repeat. Cycle time is expressed in seconds. “Circuit” refers to the current controlled by one cam and set of contact points. The time a circuit is to be on is indicated by a blue square, the time off by a blank square. Contact us with any sequencing questions.


GUIDE FOR CONSTRUCTING SPELLER SEQUENCE CHARTS


Sequence One
  • 1 on, 2 on, 3 on, 4 on, 5 on 6 on
  • All off / All on / All off
  • Repeat
Sequence One - Cycle Chart

Sequence Two
  • 1 on, 2 on, 3 on, 4 on, 5 on 6 on
  • All off
  • Repeat
Sequence Two - Cycle Chart

Sequence Three
  • 1 on-off / 2 on-off / 3 on-off /
    4 on-off / 5 on-off / 6 on-off
  • All off
  • Repeat
Sequence Three - Cycle Chart

Sequence Four
  • Same as sequence
    Three except some
    off period between
    each on segment.
Sequence Four - Cycle Chart

Sequence Five
  • Wipe on, wipe off
  • All off
  • Repeat
Sequence Five - Cycle Chart
 